Skip to content

Rolling Target Rate Sensor(s)#

After you've configured your account, you'll be able to configure rolling target rate sensors. These are configured by adding subsequent instances of the integration going through the normal flow, and selecting Rolling Target Rate in the provided menu.

These sensors calculate the lowest continuous or intermittent rates within the next available x hours, where x is configurable via the sensor, and turn on when these periods are active. If you are targeting an export meter, then the sensors will calculate the highest continuous or intermittent rates within the next available x hours and turn on when these periods are active. If you are wanting to evaluate on a fixed basis (e.g. every 24 hours), you might be interested in the standard target rate sensors

These sensors can then be used in automations to turn on/off devices that save you (and the planet) energy and money. You can go through this flow as many times as you need rolling target rate sensors.

Each sensor will be in the form binary_sensor.octopus_energy_rolling_target_{{TARGET_RATE_NAME}}.

Setup#

Hours#

The hours that you require for the sensor to find. This should be in decimal format and represent 30 minute increments. For example 30 minutes would be 0.5, 1 hour would be 1 or 1.0, 1 hour and 30 minutes would be 1.5, etc.

Hours Mode#

There are three different modes that the target rate sensor can be set to, which determines how the specified hours should be interpreted

Exact (default)#

The target rate sensor will try to find the best times for the specified hours. If less than the target hours are discovered, the sensor will not come on at all. If there are more hours than required that meet the specified requirements (e.g. below a certain rate), then it will come on for the cheapest available times up to the specified hours.

For instance if the cheapest period is between 2023-01-01T00:30 and 2023-01-01T05:00 and your target rate is for 1 hour, then it will come on between 2023-01-01T00:30 and 2023-01-01T01:30. If the available times are between 2023-01-01T00:30 and 2023-01-01T01:00, then the sensor will not come on at all.

Minimum#

The target rate sensor will try to find the best times for the specified hours. If less than the target hours are discovered, the sensor will not come on at all. If there are more hours than required that meet the specified requirements (e.g. below a certain rate), then it will come on for all discovered times.

For instance if the cheapest period is between 2023-01-01T00:30 and 2023-01-01T05:00 and your target rate is for 1 hour, then it will come on between 2023-01-01T00:30 and 2023-01-01T05:00. If the available times are between 2023-01-01T00:30 and 2023-01-01T01:00, then the sensor will not come on at all.

Maximum#

The target rate sensor will try to find the best times for the specified hours. If less than the target hours are discovered, the sensor will come on for all times that are discovered. If there are more hours than required that meet the specified requirements (e.g. below a certain rate), then it will come on for the cheapest available times up to the specified hours.

For instance if the cheapest period is between 2023-01-01T00:30 and 2023-01-01T05:00 and your target rate is for 1 hour, then it will come on between 2023-01-01T00:30 and 2023-01-01T01:30. If the available times are between 2023-01-01T00:30 and 2023-01-01T01:00, then the sensor will come on between 2023-01-01T00:30 and 2023-01-01T01:00.

Look Ahead Hours#

This is the number of hours to look ahead for the best time periods. This will include the current time period. For instance, if it's 2023-01-01T00:15 and you have your look ahead hours set to 8, then it will look for the best times between 2023-01-01T00:00 and 2023-01-01T08:00.

Evaluation mode#

Because the time frame that is being evaluated is currently moving, you might want to set how/when the target times are evaluated in order to make the selected times more or less dynamic.

All existing target rates are in the past#

This is the default way of evaluating target times. This will only evaluate new target times if no target times have been calculated or all existing target times are in the past.

Existing target rates haven't started or finished#

This will only evaluate target times if no target times have been calculated or all existing target times are either in the future or all existing target times are in the past.

For example, lets say we have a continuous rolling target which looks ahead for 8 hours and has existing target times from 2023-01-02T01:00 to 2023-01-02T02:00.

  • If the current time is 2023-01-02T00:59, then the target times will be re-evaluated and might change if the new rolling target period (i.e. 2023-01-02T00:30 to 2023-01-02T08:30) has better times than the existing target times.
  • If the current time is 2023-01-02T01:00, the the target times will not be re-evaluated because we've entered our current target times, even if the new rolling target period has cheaper times.
  • If the current time is 2023-01-02T02:01, the the target times will be re-evaluated because our existing target times are in the past and will find the best times in the new rolling target period (i.e. 2023-01-02T02:00 to 2023-01-02T10:00).

Always#

This will always evaluate the best target times for the rolling target period, even if the sensor is in the middle of an existing target time period.

For example, lets say we have a continuous rolling target which looks ahead for 8 hours and has existing target times from 2023-01-02T01:00 to 2023-01-02T02:00.

  • If the current time is 2023-01-02T00:59, then the target times will be re-evaluated and might change if the new rolling target period (i.e. 2023-01-02T00:30 to 2023-01-02T08:30) has better times than the existing target times.
  • If the current time is 2023-01-02T01:31, then the target times will be re-evaluated and might change if the new rolling target period (i.e. 2023-01-02T01:30 to 2023-01-02T09:30) has better times than the existing target times.
  • If the current time is 2023-01-02T02:01, the the target times will be re-evaluated because our existing target times are in the past and will find the best times in the new rolling target period (i.e. 2023-01-02T02:00 to 2023-01-02T10:00).

Warning

This setting means that you could end up with the sensor not turning on for the fully requested hours as the target times might be moved ahead half way through the picked times. It also could mean that the sensor doesn't come on at all during the requested look ahead hours (e.g. 8) because the cheapest period kept moving back.

Offset#

You may want your target rate sensors to turn on a period of time before the optimum discovered period. For example, you may be turning on a robot vacuum cleaner for a 30 minute clean and want it to charge during the optimum period. For this, you'd use the offset field and set it to -00:30:00, which can be both positive and negative and go up to a maximum of 24 hours. This will shift when the sensor turns on relative to the optimum period. For example, if the optimum period is between 2023-01-18T10:00 and 2023-01-18T11:00 with an offset of -00:30:00, the sensor will turn on between 2023-01-18T09:30 and 2023-01-18T10:30.

Latest Period#

Depending on how you're going to use the sensor, you might want the best period at the latest possible time. For example, you might be using the sensor to turn on an immersion heater which you'll want to come on at the end of the cheapest found period.

For instance if you turn this on and the cheapest period is between 2023-01-01T00:30 and 2023-01-01T05:00 and your target rate is for 1 hour, then it will come on between 2023-01-01T04:00 and 2023-01-01T05:00 instead of 2023-01-01T00:30 and 2023-01-01T01:30.

This feature is toggled on by the Find last applicable rates checkbox.

Invert Target Rates#

If this is checked, then the normal behaviour of the sensor will be reversed. This means if you target an import sensor, with this checked it will find the most expensive rates. Similarly if you target an export meter, with this checked it will find the cheapest rates.

Minimum/Maximum Rates#

There may be times that you want the target rate sensors to not take into account rates that are above or below a certain value (e.g. you don't want the sensor to turn on when rates go crazy or where it would be more beneficial to export). This is configured in pounds and pence format (e.g. 0.12 for 12p).

Info

If hours mode is set to minimum, then a minimum and/or maximum rate must be specified in order for the target rate sensor to know what the cut off is for discovered times.

Weighting#

Info

This is only available for continuous target rate sensors in exact hours mode.

There may be times when the device you're wanting the target rate sensor to turn on doesn't have a consistent power draw. You can specify a weighting which can be applied to each discovered 30 minute slot. This can be specified in a few different ways. Take the following example weighting for a required 2 hours.

  • 1,1,2,1 - This applies a weighting of 1 to the first, second and forth slot and a weighting of 2 to the third slot. This will try and make the cheapest slot fall on the third slot, as long as the surrounding slots are cheaper than other continuous slots.
  • *,2,1 - This applies a weighting of 1 to the first, second and forth slot and a weighting of 2 to the third slot. The * can be used as a placeholder for the standard weighting of 1 for all slots before the ones specified.
  • 1,1,2,* - This applies a weighting of 1 to the first, second and forth slot and a weighting of 2 to the third slot. The * can be used as a placeholder for the standard weighting of 1 for all slots after the ones specified.
  • 2,*,2 - This applies a weighting of 2 to the first and forth slot and a weighting of 1 to all slots in between. The * can be used as a placeholder for the standard weighting of 1 for all slots in between the specified slots.

Each slot weighting must be a whole number or decimal number and be positive.

You can also use weightings to ignore slots. This can be done by assigning a value of 0 for the desired slot.

Attributes#

The following attributes are available on each sensor

Attribute Type Description
name string The name of the sensor.
hours string The total hours are being discovered.
type string The type/mode for the target rate sensor. This will be either continuous or intermittent.
mpan string The mpan of the meter being used to determine the rates.
look_ahead_hours float The number of hours the sensor should look ahead for the best time period
target_times_evaluation_mode string The mode that determines when/how target times are picked
last_rates boolean Determines if Find last applicable rates is turned off for the sensor.
offset string The offset configured for the sensor.
is_target_export boolean Determines if the meter being targeted is exporting energy. This will change the behaviour of the sensor to look for the highest rates.
rates_incomplete boolean True if rate information is incomplete and therefore target times cannot be calculated; False otherwise.
target_times array The discovered times and rates the sensor will come on for.
overall_average_cost float The average cost/rate of all discovered times during the current 24 hour period.
overall_min_cost float The minimum cost/rate of all discovered times during the current 24 hour period.
overall_max_cost float The maximum cost/rate of all discovered times during the current 24 hour period.
current_duration_in_hours float The duration the sensor will be on for, for the current continuous discovered period. For continuous sensors, this will be the entire period. For intermittent sensors, this could be the entire period or a portion of it, depending on the discovered times. This could be none/unknown if the sensor is not currently in a discovered period.
current_average_cost float The average cost/rate for the current continuous discovered period. This could be none/unknown if the sensor is not currently in a discovered period.
current_min_cost float The min cost/rate for the current continuous discovered period. This could be none/unknown if the sensor is not currently in a discovered period.
current_max_cost float The max cost/rate for the current continuous discovered period. This could be none/unknown if the sensor is not currently in a discovered period.
next_time datetime The next date/time the sensor will come on. This will only be populated if target_times has been calculated and at least one period/block is in the future.
next_duration_in_hours float The duration the sensor will be on for, for the next continuous discovered period. For continuous sensors, this will be the entire period. For intermittent sensors, this could be the entire period or a portion of it, depending on the discovered times. This will only be populated if target_times has been calculated and at least one period/block is in the future.
next_average_cost float The average cost/rate for the next continuous discovered period. For continuous sensors, this will be the entire period. For intermittent sensors, this could be the entire period or a portion of it, depending on the discovered times. This will only be populated if target_times has been calculated and at least one period/block is in the future.
next_min_cost float The average cost/rate for the next continuous discovered period. This will only be populated if target_times has been calculated and at least one period/block is in the future.
next_max_cost float The average cost/rate for the next continuous discovered period. This will only be populated if target_times has been calculated and at least one period/block is in the future.
target_times_last_evaluated datetime The datetime the target times collection was last evaluated. This will occur if all previous target times are in the past and all rates are available for the requested future time period. For example, if you are targeting 16:00 (day 1) to 16:00 (day 2), and you only have rates up to 23:00 (day 1), then the target rates won't be calculated.

Services#

There are services available associated with target rate sensors. Please review them in the services doc.