Skip to content

Target Rate Sensor(s)#

After you've configured your account, you'll be able to configure target rate sensors. These are configured by adding subsequent instances of the integration going through the normal flow, and selecting Target Rate in the provided menu.

These sensors calculate the lowest continuous or intermittent rates within a 24 hour period and turn on when these periods are active. If you are targeting an export meter, then the sensors will calculate the highest continuous or intermittent rates within a 24 hour period and turn on when these periods are active. If you are wanting to evaluate on a rolling basis, you might be interested in the rolling target rate sensors

These sensors can then be used in automations to turn on/off devices that save you (and the planet) energy and money. You can go through this flow as many times as you need target rate sensors.

Each sensor will be in the form binary_sensor.octopus_energy_target_{{TARGET_RATE_NAME}}.

Setup#

Target Timeframe#

If you're wanting your devices to come on during a certain timeframe, for example while you're at work, you can set the minimum and/or maximum times for your target rate sensor. These are specified in 24 hour clock format and will attempt to find the optimum discovered period during these times.

The from/start time can be set in the field The minimum time to start the device and the to/end time can be set in the field The maximum time to stop the device.

If not specified, these default from 00:00:00 to 00:00:00 the following day.

If for example you want to look at prices overnight you could set the minimum time to something like 20:00 and your maximum time to something like 05:00. If the minimum time is "after" the maximum time, then it will treat the maximum time as the time for the following day.

Info

The target rate will not be evaluated until all rates are available for the specified timeframe. Therefore if we're looking between 00:00 and 00:00, full rate information must exist between this time. Whereas if times are between 10:00 and 16:00, then rate information is only needed between these times before it can be calculated.

Agile Users#

If you are an agile user, then agile prices are available from 11pm to 11pm UK time and published between 16:00 and 20:00 UK time.

Therefore, you cannot specify a timeframe that starts before 16:00 and ends after 23:00 because the target rate(s) will not be able to be calculated until part way through the specified timeframe as this is when the full set of rate information will become available. This is best illustrated with the following example, where lets say you wanted a target rate sensor to look at between 00:00 and 00:00 the next day (24 hours). Your initial available data would potentially look like the following

start end value
2023-01-01T00:00 2023-01-01T00:30 6
2023-01-01T00:30 2023-01-01T05:00 12
2023-01-01T05:00 2023-01-01T05:30 7
2023-01-01T05:30 2023-01-01T18:00 20
2023-01-01T18:00 2023-01-01T23:00 34

Where the last hour of data isn't available (because agile doesn't provide this data in the initial batch), which means the target rate sensor can't calculate the best time because it doesn't have the full data set available. If agile rate data for the next 24 hour period then became available at 16:30 and looked like the following

start end value
2023-01-01T23:00 2023-01-02T00:00 19

We now have the full data set available for the target rate sensor to calculate the best time, which would be done close to when the agile data became available (e.g. around 16:30). The result would be the target rate sensor would pick 2023-01-01T00:00 to 2023-01-01T00:30 or 2023-01-01T05:00 to 2023-01-01T05:30 because these are the cheapest times. However, these times are in the past because we're now at 16:30 and so our target rate sensor will never turn on. If a time in the future was picked to counteract this, then people would question why it didn't turn on during the cheapest times.

Therefore, we recommend you set your timeframes to 16:00/16:00 or 23:00/23:00 if you're wanting to target a full 24 hours, however other valid times might include

from/start to/end Notes
10:00 23:00 our start time is before 4pm, but our end time is not after 11pm.
16:30 23:30 our start time is after 4pm, so our end time can be after 11pm.
17:00 14:00 our start time is after 4pm and our end time is before our start time so therefore for the next day. Doing this might delay when the target rate sensor is calculated depending on when the rates are made available for the next day (e.g. if they're late for publishing).

This is not automatically done by the integration as I didn't want to cause confusion for users when they didn't set anything nor did I want behaviour to implicitly change when users switch tariffs.

See the examples below for how this can be used and how rates will be selected.

Hours#

The hours that you require for the sensor to find. This should be in decimal format and represent 30 minute increments. For example 30 minutes would be 0.5, 1 hour would be 1 or 1.0, 1 hour and 30 minutes would be 1.5, etc.

Hours Mode#

There are three different modes that the target rate sensor can be set to, which determines how the specified hours should be interpreted

Exact (default)#

The target rate sensor will try to find the best times for the specified hours. If less than the target hours are discovered, the sensor will not come on at all. If there are more hours than required that meet the specified requirements (e.g. below a certain rate), then it will come on for the cheapest available times up to the specified hours.

For instance if the cheapest period is between 2023-01-01T00:30 and 2023-01-01T05:00 and your target rate is for 1 hour, then it will come on between 2023-01-01T00:30 and 2023-01-01T01:30. If the available times are between 2023-01-01T00:30 and 2023-01-01T01:00, then the sensor will not come on at all.

Minimum#

The target rate sensor will try to find the best times for the specified hours. If less than the target hours are discovered, the sensor will not come on at all. If there are more hours than required that meet the specified requirements (e.g. below a certain rate), then it will come on for all discovered times.

For instance if the cheapest period is between 2023-01-01T00:30 and 2023-01-01T05:00 and your target rate is for 1 hour, then it will come on between 2023-01-01T00:30 and 2023-01-01T05:00. If the available times are between 2023-01-01T00:30 and 2023-01-01T01:00, then the sensor will not come on at all.

Maximum#

The target rate sensor will try to find the best times for the specified hours. If less than the target hours are discovered, the sensor will come on for all times that are discovered. If there are more hours than required that meet the specified requirements (e.g. below a certain rate), then it will come on for the cheapest available times up to the specified hours.

For instance if the cheapest period is between 2023-01-01T00:30 and 2023-01-01T05:00 and your target rate is for 1 hour, then it will come on between 2023-01-01T00:30 and 2023-01-01T01:30. If the available times are between 2023-01-01T00:30 and 2023-01-01T01:00, then the sensor will come on between 2023-01-01T00:30 and 2023-01-01T01:00.

Offset#

You may want your target rate sensors to turn on a period of time before the optimum discovered period. For example, you may be turning on a robot vacuum cleaner for a 30 minute clean and want it to charge during the optimum period. For this, you'd use the offset field and set it to -00:30:00, which can be both positive and negative and go up to a maximum of 24 hours. This will shift when the sensor turns on relative to the optimum period. For example, if the optimum period is between 2023-01-18T10:00 and 2023-01-18T11:00 with an offset of -00:30:00, the sensor will turn on between 2023-01-18T09:30 and 2023-01-18T10:30.

Re-evaluate within time frame#

Depending on how you're going to use the sensor, you might want the best period to be found throughout the day so it's always available. For example, you might be using the sensor to turn on a washing machine which you might want to come on at the best time regardless of when you use the washing machine. You can activate this behaviour by setting the Re-evaluate multiple times a day checkbox.

Warning

Using this can result in the sensor coming on more than the target hours, and therefore should be used in conjunction with other sensors. Depending on how long your target timeframe is, upon each re-evaluation the picked times will get steadily worse.

However, you might also only want the target time to occur once during each timeframe so once the best time for that day has passed it won't turn on again until the next timeframe. For example, you might be using the sensor to turn on something that isn't time critical and could wait till the next timeframe like a charger. This is the default behaviour and is done by not setting the Re-evaluate multiple times a day checkbox.

Info

The next set of target times will not be calculated until all target times are in the past. This will have an effect on the next set of attributes on the sensor.

Latest Period#

Depending on how you're going to use the sensor, you might want the best period at the latest possible time. For example, you might be using the sensor to turn on an immersion heater which you'll want to come on at the end of the cheapest found period.

For instance if you turn this on and the cheapest period is between 2023-01-01T00:30 and 2023-01-01T05:00 and your target rate is for 1 hour, then it will come on between 2023-01-01T04:00 and 2023-01-01T05:00 instead of 2023-01-01T00:30 and 2023-01-01T01:30.

This feature is toggled on by the Find last applicable rates checkbox.

Invert Target Rates#

If this is checked, then the normal behaviour of the sensor will be reversed. This means if you target an import sensor, with this checked it will find the most expensive rates. Similarly if you target an export meter, with this checked it will find the cheapest rates.

Minimum/Maximum Rates#

There may be times that you want the target rate sensors to not take into account rates that are above or below a certain value (e.g. you don't want the sensor to turn on when rates go crazy or where it would be more beneficial to export). This is configured in pounds and pence format (e.g. 0.12 for 12p).

Info

If hours mode is set to minimum, then a minimum and/or maximum rate must be specified in order for the target rate sensor to know what the cut off is for discovered times.

Weighting#

Info

This is only available for continuous target rate sensors in exact hours mode.

There may be times when the device you're wanting the target rate sensor to turn on doesn't have a consistent power draw. You can specify a weighting which can be applied to each discovered 30 minute slot. This can be specified in a few different ways. Take the following example weighting for a required 2 hours.

  • 1,1,2,1 - This applies a weighting of 1 to the first, second and forth slot and a weighting of 2 to the third slot. This will try and make the cheapest slot fall on the third slot, as long as the surrounding slots are cheaper than other continuous slots.
  • *,2,1 - This applies a weighting of 1 to the first, second and forth slot and a weighting of 2 to the third slot. The * can be used as a placeholder for the standard weighting of 1 for all slots before the ones specified.
  • 1,1,2,* - This applies a weighting of 1 to the first, second and forth slot and a weighting of 2 to the third slot. The * can be used as a placeholder for the standard weighting of 1 for all slots after the ones specified.
  • 2,*,2 - This applies a weighting of 2 to the first and forth slot and a weighting of 1 to all slots in between. The * can be used as a placeholder for the standard weighting of 1 for all slots in between the specified slots.

Each slot weighting must be a whole number or decimal number and be positive.

You can also use weightings to ignore slots. This can be done by assigning a value of 0 for the desired slot.

Free Electricity Weighting#

If you subscribed to Octopus Energy's free electricity sessions, then you might want your sensor to favour the hours that these are available, but potentially still favour other times if they're cheaper by a larger portion. Here is where you can have a weighting applied to the rate during free electricity sessions to have them favour them in certain scenarios.

For example, if we have the following rates

Start End Rate Is Free Electricity Period
2024-11-26 10:00:00 2024-11-26 10:30:00 0.1p N
2024-11-26 10:30:00 2024-11-26 11:00:00 0.1p N
2024-11-26 11:00:00 2024-11-26 11:30:00 0.2p Y
2024-11-26 11:30:00 2024-11-26 12:00:00 0.2p Y
2024-11-26 12:00:00 2024-11-26 12:30:00 0.3p N
2024-11-26 12:30:00 2024-11-26 13:00:00 0.3p N

If we had a target rate sensor of 1 hour, the following would occur with the following weightings

| Weighting | Period | Reason | | 1 | 2024-11-26 10:00:00-2024-11-26 11:00:00 | Cheapest period | | 0.5 | 2024-11-26 10:00:00-2024-11-26 11:00:00 | Cheapest period would be 0.1p, free electricity period would be 0.1p. By default, target rates favour the earliest sessions. | | 0.2 | 2024-11-26 11:00:00-2024-11-26 12:00:00 | Cheapest period would be 0.1p, free electricity period would be 0.02p. | | 0 | 2024-11-26 11:00:00-2024-11-26 12:00:00 | Cheapest period would be 0.1p, free electricity period would be 0p. This will always go for free electricity sessions if available. |

Attributes#

The following attributes are available on each sensor

Attribute Type Description
name string The name of the sensor.
hours string The total hours are being discovered.
type string The type/mode for the target rate sensor. This will be either continuous or intermittent.
mpan string The mpan of the meter being used to determine the rates.
rolling_target boolean Determines if Re-evaluate multiple times a day is turned on for the sensor.
last_rates boolean Determines if Find last applicable rates is turned off for the sensor.
offset string The offset configured for the sensor.
start_time string The start time configured for the sensor.
end_time string The end time configured for the sensor.
is_target_export boolean Determines if the meter being targeted is exporting energy. This will change the behaviour of the sensor to look for the highest rates.
rates_incomplete boolean True if rate information is incomplete and therefore target times cannot be calculated; False otherwise.
target_times array The discovered times and rates the sensor will come on for.
overall_average_cost float The average cost/rate of all discovered times during the current 24 hour period.
overall_min_cost float The minimum cost/rate of all discovered times during the current 24 hour period.
overall_max_cost float The maximum cost/rate of all discovered times during the current 24 hour period.
current_duration_in_hours float The duration the sensor will be on for, for the current continuous discovered period. For continuous sensors, this will be the entire period. For intermittent sensors, this could be the entire period or a portion of it, depending on the discovered times. This could be none/unknown if the sensor is not currently in a discovered period.
current_average_cost float The average cost/rate for the current continuous discovered period. This could be none/unknown if the sensor is not currently in a discovered period.
current_min_cost float The min cost/rate for the current continuous discovered period. This could be none/unknown if the sensor is not currently in a discovered period.
current_max_cost float The max cost/rate for the current continuous discovered period. This could be none/unknown if the sensor is not currently in a discovered period.
next_time datetime The next date/time the sensor will come on. This will only be populated if target_times has been calculated and at least one period/block is in the future.
next_duration_in_hours float The duration the sensor will be on for, for the next continuous discovered period. For continuous sensors, this will be the entire period. For intermittent sensors, this could be the entire period or a portion of it, depending on the discovered times. This will only be populated if target_times has been calculated and at least one period/block is in the future.
next_average_cost float The average cost/rate for the next continuous discovered period. For continuous sensors, this will be the entire period. For intermittent sensors, this could be the entire period or a portion of it, depending on the discovered times. This will only be populated if target_times has been calculated and at least one period/block is in the future.
next_min_cost float The average cost/rate for the next continuous discovered period. This will only be populated if target_times has been calculated and at least one period/block is in the future.
next_max_cost float The average cost/rate for the next continuous discovered period. This will only be populated if target_times has been calculated and at least one period/block is in the future.
target_times_last_evaluated datetime The datetime the target times collection was last evaluated. This will occur if all previous target times are in the past and all rates are available for the requested future time period. For example, if you are targeting 16:00 (day 1) to 16:00 (day 2), and you only have rates up to 23:00 (day 1), then the target rates won't be calculated.

Services#

There are services available associated with target rate sensors. Please review them in the services doc.

Examples#

Let's look at a few examples. Let's say we have the the following (unrealistic) set of rates:

start end value
2023-01-01T00:00 2023-01-01T00:30 6
2023-01-01T00:30 2023-01-01T05:00 12
2023-01-01T05:00 2023-01-01T05:30 7
2023-01-01T05:30 2023-01-01T18:00 20
2023-01-01T18:00 2023-01-01T23:30 34
2023-01-01T23:30 2023-01-02T00:30 5
2023-01-02T00:30 2023-01-02T05:00 12
2023-01-02T05:00 2023-01-02T05:30 7
2023-01-02T05:30 2023-01-02T18:00 20
2023-01-02T18:00 2023-01-02T23:00 34
2023-01-02T23:30 2023-01-03T00:00 6

Continuous#

If we look at a continuous sensor that we want on for 1 hour.

If we set no from/to times, then our 24 hour period being looked at ranges from 00:00:00 to 23:59:59.

The following table shows what this would be like.

current date/time period Re-evaluate multiple times a day reasoning
2023-01-01T00:00 2023-01-01T00:00 - 2023-01-01T01:00 false While 5 is our lowest rate within the current 24 hour period, it doesn't cover our whole 1 hour and is next to a high 34 rate. A rate of 6 is the next available rate with a low following rate.
2023-01-01T01:00 2023-01-02T00:00 - 2023-01-02T01:00 false Our lowest period is in the past, so we have to wait until our target period has passed to look at the next evaluation period.
2023-01-01T01:00 2023-01-01T04:30 - 2023-01-01T05:30 true The rate of 6 is in the past, so 7 is our next lowest rate. 12 is smaller rate than 20 so we start in the rate period before to fill our desired hour.
2023-01-01T23:30 None true There is no longer enough time available in the current 24 hour period, so we have to wait until our target period has passed to look at the next evaluation period.

If we set our from/to times for 05:00 to 19:00, we then limit the period that we look at. The following table shows what this would be like.

current date/time period Re-evaluate multiple times a day reasoning
2023-01-01T00:00 2023-01-01T05:00 - 2023-01-01T06:00 false The rate of 12 is no longer available as it's outside of our from time.
2023-01-01T06:30 2023-01-02T05:00 - 2023-01-02T06:00 false Our lowest period is in the past, so we have to wait until our target period has passed to look at the next evaluation period.
2023-01-01T06:30 2023-01-01T06:30 - 2023-01-01T07:30 true The rate of 7 is in the past, so we must look for the next lowest combined rate.
2023-01-01T18:00 2023-01-01T18:00 - 2023-01-01T19:00 true The rate of 20 is in the past, so we must look for the next lowest combined rate which is 34.
2023-01-01T18:30 None true There is no longer enough time available within our restricted time, so we have to wait until our target period has passed to look at the next evaluation period.

If we set our from/to times to look over two days, from 20:00 to 06:00, we then limit the period that we look at to overnight. The following table shows what this would be like.

current date/time period Re-evaluate multiple times a day reasoning
2023-01-01T20:00 2023-01-01T23:30 - 2023-01-02T01:30 false Our lowest rate of 5 now falls between our overnight time period so is available.
2023-01-02T02:00 2023-01-01T23:30 - 2023-01-02T01:30 false Our lowest period is in the past, so we have to wait until our target period has passed to look at the next evaluation period.
2023-01-02T02:00 2023-01-02T04:30 - 2023-01-02T05:30 true The rate of 5 is in the past, so we must look for the next lowest combined rate, which includes our half hour rate at 7.
2023-01-02T05:30 None true There is no longer enough time available within our restricted time, so we have to wait until our target period has passed to look at the next evaluation period.

If we set an offset of -00:30:00, then while the times might be the same, the target rate sensor will turn on 30 minutes before the select rate period starts. Any set time restrictions will not include the offset.

Intermittent#

If we look at an intermittent sensor that we want on for 1 hour total (but not necessarily together).

If we set no from/to times, then our 24 hour period being looked at ranges from 00:00:00 to 23:59:59.

The following table shows what this would be like.

current date/time period Re-evaluate multiple times a day reasoning
2023-01-01T00:00 2023-01-01T00:00 - 2023-01-01T00:30, 2023-01-01T23:30 - 2023-01-02T00:00 false Our sensor will go on for 30 minutes at the cheapest rate, then 30 minutes at the next cheapest rate.
2023-01-01T01:00 2023-01-01T00:00 - 2023-01-01T00:30, 2023-01-01T23:30 - 2023-01-02T00:00 false Our sensor will go on for 30 minutes at the cheapest rate, which will be in the past, then 30 minutes at the next cheapest rate.
2023-01-01T01:00 2023-01-01T05:00 - 2023-01-01T05:30, 2023-01-01T23:30 - 2023-01-02T00:00 true Our sensor will go on for 30 minutes at the second cheapest rate, then 30 minutes at the third cheapest rate.
2023-01-01T23:30 None true There is no longer enough time available in the current 24 hour period, so we have to wait until our target period has passed to look at the next evaluation period.

If we set our from/to times for 05:00 to 19:00, we then limit the period that we look at. The following table shows what this would be like.

current date/time period Re-evaluate multiple times a day reasoning
2023-01-01T00:00 2023-01-01T05:00 - 2023-01-01T05:30, 2023-01-01T05:30 - 2023-01-01T06:00 false Our cheapest rates are outside our target range, so we need to look at the next cheapest. Luckily on our scenario the two cheapest rates are next to each other.
2023-01-01T06:30 2023-01-01T05:00 - 2023-01-01T05:30, 2023-01-01T05:30 - 2023-01-01T06:00 false Both of our cheapest rates in the target range are in the past.
2023-01-01T06:30 2023-01-01T06:30 - 2023-01-01T07:00, 2023-01-01T07:00 - 2023-01-01T07:30 true Both of our cheapest rates in the target range are in the past, so we must look for the next lowest combined rate.
2023-01-01T18:30 None true There is no longer enough time available within our restricted time, so we have to wait until our target period has passed to look at the next evaluation period.

If we set our from/to times to look over two days, from 20:00 to 06:00, we then limit the period that we look at to overnight. The following table shows what this would be like.

current date/time period Re-evaluate multiple times a day reasoning
2023-01-01T20:00 2023-01-01T23:30 - 2023-01-02T00:30, 2023-01-02T05:00 - 2023-01-02T05:30 false Our lowest rate of 5 now falls between our overnight time period so is available.
2023-01-02T02:00 2023-01-01T23:30 - 2023-01-02T00:30, 2023-01-02T05:00 - 2023-01-02T05:30 false Our lowest period is in the past, but we still have a rate in the future so our sensor will only come on once.
2023-01-02T02:00 2023-01-02T02:00 - 2023-01-02T02:30, 2023-01-02T05:00 - 2023-01-02T05:30 true The rate of 5 is in the past, so we must look for the next lowest combined rate, which includes our half hour rate at 7.
2023-01-02T05:30 None true There is no longer enough time available within our restricted time, so we have to wait until our target period has passed to look at the next evaluation period.

If we set an offset of -00:30:00, then while the times might be the same, the target rate sensor will turn on 30 minutes before the select rate period starts. Any set time restrictions will not include the offset.